Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Leg J ; 91(2): 109-112, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36695005

RESUMO

BACKGROUND: Three-dimensional (3-D) modelling can be a useful technical aid and we used it to reconstruct a homicide scene to corroborate the statement of an eyewitness. 3-D modelling of the bloodstain was conducted by Micro Smith Poser 11 and Autodesk 3-Ds Max software. The technique was found to be easily understandable by the police and judiciary in the interpretation of the sequence of the events of the crime. It refuted the eye-witness's account of the actions of the accused who was charged with murder and allowed collection, storage and retrieval of the patho-anatomic information about the deceased. CONCLUSION: The checks on the accuracy of statements given by eye-witnesses that can be provided by 3-D modelling may change the outcome of criminal investigations in future.


Assuntos
Manchas de Sangue , Homicídio , Humanos , Crime , Aplicação da Lei , Polícia
2.
J Appl Crystallogr ; 49(Pt 4): 1209-1222, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27504076

RESUMO

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the 'glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO3)2. The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...